7
TYPICAL APPLICATIONS (Continued)
Remote 1
Ground 1
(G/R) P 8
(BR/R) P 9
Momentary
Single Pole, N. O.
Single Throw
Switch
66 Block
Equipment
Customer Provided
Figure 7 - Remote/Confirmation Pushbutton for Manual Door Release
Station 1
Ground 1
(BL/R) P 6
(BR/R) P 9
66 Block
Equipment
Customer Provided
-
+
Indicator
50mA, -24VDC
current maximum
available for
indicator
Figure 8 - Handsfree Indicator
Door Sensor 1
Ground 1
(R/BR) P34
(BR/R) P 9
66 Block
Equipment
Customer Provided
Magnetic Door
Switch
Figure 9 - Door Sensor
Unauthorized Door Opening (GR/W) P 3
66 Block
Equipment
Customer Provided
Figure 10 - Unauthorized Door Opening
-24VDC
larm
To Alarm, auto dialer, etc.
Customer provided low current relay
-24VDC, 125mA max
* Signal out only, will not drive alarm directly
** Ground must be common
Common Audible Make
Common Audible Break
(W/O) P27
(W/GR) P28
Bells, buzzers, etc.
66 Block
Equipment
Customer Provided
A
lerting Device
Power Supply
Common Audible Stationary (O/W) P 2
NO
Com
NC
Figure 11 - Remote Signalling Relay
Signal Out
NO = Normally Open
NC = Normally Closed
Relay contacts rated at 1A –24VDC
Vue de la page 6